1. Colorful touch LCD, IP65 protection degree 2. 6 time periods for battery charging/discharging
current of 240A
Grid peak shaving function
Add to Cart
8/10/12Kw Output Voltage 380VAC ± 5% DC/AC 50Hz/60Hz Solar Inverter Kit with Best Sale



| Model | SUN-6K-SG04LP3-EU | SUN-8K-SG04LP3-EU | SUN-10K-SG04LP3-EU | SUN-12K-SG04LP3-EU | ||||
| Battery Input Data | | | | | ||||
| Battery Type | Lead-acid or Lithium-ion | | | | ||||
| Battery Voltage Range (V) | 40~60V | | | | ||||
| Max. Charging Current (A) | 150 | 190 | 210 | 240 | ||||
| Max. Discharging Current (A) | 150 | 190 | 210 | 240 | ||||
| External Temperature Sensor | Optional | | | | ||||
| Charging Strategy for Li-Ion Battery | Self-adaption to BMS | | | | ||||
| PV String Input Data | | | | | ||||
| Max. DC Input Power (W) | 7800 | 10400 | 13000 | 15600 | ||||
| PV Input Voltage (V) | 550 (160~800) | | | | ||||
| MPPT Range (V) | 350-650 | | | | ||||
| Start-up Voltage (V) | 160 | | | | ||||
| PV Input Current (A) | 17+17 | 26A+13A | 34+17 | | ||||
| No.of MPPT Trackers | 2 | | | | ||||
| No.of Strings Per MPPT Tracker | 1 | 2+1 | 2+2 | | ||||
| AC Output Data | | | | | ||||
| Rated AC Output and UPS Power (W) | 6000 | 8000 | 10000 | 12000 | ||||
| Max. AC Output Power (W) | 6600 | 8800 | 11000 | 13200 | ||||
| Peak Power (off grid) | 2 times of rated power, 10 S | | | | ||||
| AC Output Rated Current (A) | 9.1/8.7 | 12.1/11.6 | 15.2/14.5 | 18.2/17.4 | ||||
| Max. Continuous AC Passthrough (A) | 35A | 40A | 50A | | ||||
| Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380, 230/400Vac | | | | ||||
| Grid Type | Three phase | | | | ||||
| Current Harmonic Distortion | THD<3%(Linear load<1.5%) | | | | ||||
| Efficiency | | | | | ||||
| Max. Efficiency | 97.60% | | | | ||||
| Euro Efficiency | 97.00% | | | | ||||
| MPPT Efficiency | 99.90% | | | | ||||
| Protection | | | | | ||||
| Integrated | PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection | | | | ||||
| Output Over Voltage Protection | DC Type II / AC Type II | | | | ||||
| Certifications and Standards | | | | | ||||
| Grid Regulation | VDE 0126,AS4777,NRS2017,G98,G99,IEC61683,IEC62116,IEC61727 | | | | ||||
| Safety Regulation | IEC62109-1, IEC62109-2 | | | | ||||
| EMC | EN61000-6-1, EN61000-6-3 | | | | ||||
| General Data | | | | | ||||
| Operating Temperature Range (℃) | -25~60℃, >45℃ Derating | | | | ||||
| Cooling | Fan | | | | ||||
| Noise (dB) | <30 | | | | ||||
| Communication with BMS | RS485; CAN | | | | ||||
| Weight (kg) | 33.6 | | | | ||||
| Size (mm) | 670×420×233mm | | | | ||||
| Protection Degree | IP65 | | | | ||||
| Installation Style | Wall-mounted | | | | ||||
| Warranty | 5 years | | | | ||||